The Burrus home in St. Peters is a 2,394-square-foot house on 24 ducts. Its system is not built one way throughout. Some runs are galvanized sheet metal and others are framed joist cavities panned with metal, and the two had collected very different things. One photo pair follows each duct type, shot before and after from the same position.
Burrus
The metal main air duct carried a fine layer across its floor and pale speckling over the upper surfaces, with coarser material piled at the damper. The framed return was worse: a deep bed of dust and grit the length of the run, cobwebs across the board above it, and household debris through it.
Both constructions were cleaned, and they do not behave the same. Metal gives material up readily, while a timber cavity holds on to it. All 24 runs were cleaned and photographed from fixed points, before and after. That is residential air duct cleaning as SafeAir runs it across St. Peters.
Both after photographs were taken from the same positions as the before shots. The main air duct shows bare galvanized steel, the installer's marking legible on the wall. The framed return shows clean board and timber with the metal pan visible beneath. All 24 ducts were done in one visit.